Abstract

Electricity plays an important role in the contemporary life, and it has become indispensable nowadays. Reducing the peak electricity load and increasing the load factor have been considered as one of the main tasks that have to be accomplished by both electricity generation-side and demand-side managements.
The residential sector of Libya consumes over 31% of the total sold electricity, and 29.8% of that is delivered to the electric water heating load. This is an inefficient way of electricity utilization. Usually, the electricity supplier in Libya used to increase the local generation capacity or import electricity from neighboring countries. Both solutions did not resolve the problem. This work attempts to investigate the effect of replacing electric water heaters in the residential sector of Libya by solar water heaters on reducing the electricity peak load and increasing the load factor. The results show that on average 3% of the peak load demand can be saved. This is equivalent to 149.5 MW of reduced power. The study also revealed that the annual amount of energy saved is up to 2.55TWh, and the load factor is improved by 2% (i.e. from 65% to 67%). This saved energy is equivalent to a power plant with a nominal capacity of 448 MW considering a load factor of 0.65.

Downloads

Download data is not yet available.

Metrics

Metrics Loading ...

References

. Missaoui R., Ben Hassine H., Mourtada A., 2012, Energy efficiency indicators in the Southern and Eastern Mediterranean countries, Regional report, RCREEE.

. GECOL, 2010, General Electric Company Annual Report, 2010.

. Moreau A. 2010. “Control strategy for domestic water heaters during peak periods and its impact on the demand for electricity”. DOI: https://doi.org/10.1016/j.egypro.2011.10.140

. Planning electric power system studies for Libya: demand forecasting & generation expansion planning until 2025, 2008, Final report, planning Dept. GPCoEWG and KEPCO, GECOL.

. Khawaja Sami, David Korn, and Josh Keeling, 2010, Report: Winter Load Research for General Electric Company of Libya, The Cadums Group.

. Khawaja Sami, David Korn, and Josh Keeling, 2010, Report: Summer Load Research for General Electric Company of Libya, The Cadums Group.

. Ekhlat, M., Azgalah A., and Madhon, M., 2009, Support general electric network of Libya by covering hot water load in the residential sector with solar water heaters, GECoL, internal report.

. Abdunnabi M, 2012. “Optimum Values of Tank Volume to Collector Area Ratios of Thermosyphon Solar Water Heaters for Libyan Families”, Journal of Solar Energy and Sustainable Development, JSESD, No 1, Vol,1, CSERS, 2012. DOI: https://doi.org/10.51646/jsesd.v1i1.104

. Abdunnabi, M. and Berwian B, 2005, Economic and environmental benefits of the replacement of Solar water heaters instead of electric heaters in Libya, Scientific Journal of Science, Vol(13), July 2005 (Arabic).

. Statistic report, General Authority for Information (GAI), 2007, Libya.

. Klein, S.A., et al, 2010, TRNSYS 17: a transient simulation program, Solar Energy Laboratory : Madison University of Wisconsin, USA.