Optimum Sizing of Residential Active Solar Water Heating Systems for Libyan Families

Authors

  • M.J.R. Abdunnabi Center for Solar Energy Research and Studies, Tripoli-Libya
  • M. Al-Ahjal Libyan Academy, School of Engineering and Applied Science, Mechanical Department, Tripoli-Libya
  • Ibrahim O. Rahoma College of Engineering Technology. Janzour-Libya

Keywords:

active solar water heaters , optimization , TRNSYS simulation

Abstract

This paper investigates the optimum sizing of active solar water heaters for the residential sector in Libya according to family size, typical weather conditions, and typical operating conditions. An active solar water heating system model built in TRNSYS was used to evaluate the thermal performance of the system, while the optimization process was accomplished using the genetic algorithm technique. Nine design parameters were chosen for the optimization, and their search space of the problem under investigation was defied.
Three Libyan family sizes were suggested for the investigation for optimum solar water heaters; 4, 6, and 8 people. The Pareto optimal front of the cost function for the three cases was plotted as a function of system’s solar fraction. The design parameters of some feasible non-dominated solutions are presented in tables. These results confirm the effectiveness of using the genetic algorithm technique for solar water heating system optimization

Downloads

Download data is not yet available.

Metrics

Metrics Loading ...

References

. Morrison, G. L. and J. E. Braun, “System modelling and operation characteristics of thermosyphon solar water

heaters, Solar Energy”, vol. 34, pp. 389-405, 1985.

. Shariah, A. M., Douglas, C. Hittle and Lof, G.O.G, “Computer simulation and optimization of design parameters for thermosyphon solar water heater”, in Proc. Joint solar Engineering Conference ASME, pp. 393-399, 1994.

. Shariah, A. and Shalabi, B., “Optimal design for a thermosyphon solar water heater”, Renewable Energy,

Vol. 11, No. 3 pp. 351-361, 1994.

. Hasan A., “Thermosyphon solar water heaters: effect of storage tank volume and configuration on efficiency”,

Energy Conversion and Management, Vol. 38, No. 9, pp. 847-854, 1997.

. Barley C. D,, and Winn C. B., “Optimal sizing of solar collector by the method of relative areas”, Solar Energy,

Vol. 21, pp. 279-289, 1978.

. Michelson E., ”Multivariate optimisation of a solar water heating system using SIMPLEX method”, Solar

Energy, Vol. 29, No. 2, pp. 89-99, 1982.

. Pedersen P. V., “System design optimisation for large building-integrated solar heating system for domestic

hot water”, Solar Energy, Vol. 50, No. 3, pp. 267-273, 1993.

. Kulkarni G. N., Kedare S. B., and Bandyopadhyay S., “Determination of design space and optimisation of solar water heating systems”, Solar Energy, Vol. 81, pp. 958-968, 1993.

. Gupta, C. L. and H. P. Garg, “System design in solar water heaters with natural circulation”, Solar Energy,

Vol. 12, pp. 163-182, 1968.

. Norton B. and Probert, S. D., “Optimising the design of natural-circulation solar-energy water heaters”, in

Proc. Passive and Low Energy Architecture, pp. 587-596, 1983.

. Malkin, M. P., Klein, S. A., Duffi J. A., Copsey, A. B., “Design methods for thermosyphon solar domestic hot

water systems”, Journal of Solar Energy Engineering, Transactions of the ASME, Vol. 109, No. 2, pp. 150-155,

. Shariah, A. M. and G. O. G. Löf, “The optimization of tank-volume-to-collector-area ratio for a thermosyphon solar water heater”, Renewable Energy, Vol. 7, No. 3, pp. 289-300, 1996.

. Kicsiny R., Farkas I., “Improved diffrential control for solar heating Systems”, Solar Energy, Vol 86, No. 11, pp.

–3498, 2012.

. Jason Ng, Cheng Hin., and Radu Zmeureanu., “Optimization of Residential Solar Combi-system for Minimum Life Cycle Energy and Cost”, Proc. of eSim 2012: Th Canadian Conference on Building Simulation, pp 29-107, 2012.

. Krause M., Vajen K., Wiese F., Ackermann H., “Investigations on optimizing large solar thermal systems”, Solar Energy, Vol. 73, No. 4, pp. 217–225, 2002.

. Chang K. K, and Minardi A., “An optimisation formulation for solar heating systems”, Solar Energy, Vol. 24, pp. 99-103, 1980.

. Govind N. Kulkarni, Shireesh B. Kedare, Santanu Bandyopadhyay, “Determination of Design Space and

Optimization of Solar Water Heating Systems”, Solar Energy, Vol. 81, pp. 958-968, 2007.

. Pereira M .C, Gordon J .M ., Rabl A ., and Zarmi Y., “Design and optimization of solar industrial hot water

systems with storage”, Solar Energy, Vol. 32, No. 1, pp. 121-133, 1984.

. Branemuehl M. J, Beckman W. A., “Economic evolution and optimization of solar heating systems”, Solar

Energy, Vol 23, pp. 1910, 1979.

. Abdunnabi M., “Optimum values of tank volume to collector area ratios of thermosyphon solar water

heaters for Libyan families”, Journal of Solar Energy and Sustainable Development (JSESD), Vol. 1, No. 1, pp.

-31, 2012

Downloads

Published

2017-06-30

How to Cite

[1]
M. . Abdunnabi, M. . Al-Ahjal, and I. O. . Rahoma, “Optimum Sizing of Residential Active Solar Water Heating Systems for Libyan Families”, jsesd, vol. 6, no. 1, pp. 18–26, Jun. 2017.

Issue

Section

Articles